FAMUS
FAMUS

EGLIN Store Separation

  • Overview

This problem is a CFD reproduction of a wind tunnel experiment conducted at the U.S. Air Force’s Eglin Base to analyze the interference effects that occur when an aircraft separates an externally mounted store.

The moving-body flow analysis is validated by comparing the trajectory and attitude angles of the external store, as well as the pressure coefficient.


39e0fe5d5e1a4.png

<External Store Separation Wind Tunnel Experiment >



  • Problem Definition
  • Compressible unsteady flow
  • Mach number: 0.95
  • Static pressure: 35,988 Pa
  • Static temperature: 236.639 K
  • Angle of attack: 0°


f191a34ca2578.png <Eglin External Store Separation Problem Geometry >


  • FAMUS Setup

  • Octree grid points: approximately 2.69 million
  • Prism grid points: approximately 2.48 million
  • Flow type: compressible unsteady flow
  • Viscous model: inviscid / Euler
  • Spatial discretization: 3rd-order MLP
  • Temporal discretization: LU-SGS
  • Flux scheme: M-AUSMPW+
  • Analysis Results

  • Pressure coefficient contour
  • External store trajectory


17ff06b39c2eb.png

Pressure Coefficient Comparison


5df482bf18789.png

Trajectory and Attitude Angle Comparison


7da84b08d5fea.png


References

Heim, E. R. CFD wing/pylon/finned store mutual interference wind tunnel experiment. Arnold Engineering Development Center, Air Force Systems Command, United States Air Force, 1991.

Sunay, E. Y., et al. Numerical simulations of store separation trajectories using the EGLIN test. Scientific Technical Review, 63(1) ,2013.